When understanding electric actuators we will find that products are generally divided into two parts: one is the power part, and the other is the mechanical limit control device. When producing and processing these two parts, the requirements for each product accessory are relatively high. Only by ensuring that the quality of each accessory is better can the production quality be guaranteed. Therefore, electric actuators the installation and maintenance of the product require you to learn.

 

1, electric actuators It is a non-explosion-proof product, and dangerous gas environments should be avoided during installation.
2. It can be installed indoors or outdoors, but rain, other splashing liquids, and direct sunlight should be avoided.
3. Before installation, clean the pipeline and install a filter and drain valve on the valve inlet side to remove impurities such as gravel and rust.
4. Vertical installation is preferred. It can also be installed at any angle, but the position of the cable interface should be higher than the direction of the cable or conduit to prevent water from flowing into the actuator along the cable or conduit.
5. The flange connection of the valve body should maintain natural coaxiality to avoid shear stress, and the connecting bolts should be tightened evenly.
6. Space should be reserved for installation, wiring, manual operation, disassembly, and maintenance.
7. In important occasions, it is necessary to add a bypass pipeline so that it can be switched to manual operation in case of failure or maintenance.
8. The valve body needs to be insulated like a pipeline, especially when used in high-temperature media. Otherwise, the normal operation of the electric actuator will be affected by the high ambient temperature.

 

When we start electric actuators the following stops are required to obtain good equipment results. The intensity test must be stopped within the equipment time to ensure that the sealing surface does not leak or leak. Therefore, after completing the equipment steps of the electric actuator and using different connection methods for the end and connector (mainly screw, welding, etc.), electric actuators these details must be paid attention to during installation. To learn more about the maintenance details of electric actuators, you can contact Dalian Hongbo Electric Power Engineering Co., Ltd. for detailed consultation. Dalian Hongbo Electric Power Engineering Co., Ltd. agents a full range of CDG products, including: CO series control valves, BA series ball valves, GA series gate valves, BU series butterfly valves, GL series globe valves, CH series check valves, general valves, electric actuators, pneumatic actuators, hydraulic actuators, oil stations, etc. The company is strong and is a worthwhile company to cooperate with.